Hanbon

Bio-Lab¢ç Laboratory Chromatography System

Bio-Lab¢ç Laboratory Chromatography SystemÀº ÇѺ»(Hanbon)¿¡¼­ µ¶ÀÚÀûÀ¸·Î °³¹ßÇÑ ½Å¼Ó¼º ¹× ½Å·Ú¼ºÀÌ ÀÖ´Â °íÈ¿À² Automatic Chromatography ÀåÄ¡ÀÔ´Ï´Ù. ÀÌ ½Ã½ºÅÛÀº ¸¶ÀÌÅ©·Î±×·¥ºÎÅÍ ±×·¥ ´ÜÀ§ÀÇ »ý¹° ºÐÀÚµéÀ» ½Å¼ÓÇÏ°Ô Á¤Á¦ÇÏ´Â µ¥ »ç¿ëµÉ ¼ö ÀÖÀ¸¸ç, Protein, Polypeptide, Nucleic Acids µî°ú °°Àº »ý¹° ºÐÀÚµéÀ» ´ë»óÀ¸·Î ÇÕ´Ï´Ù. ½Ã½ºÅÛÀº ¸ðµâÇü ¼³°è¿Í Áö´ÉÇü ¼ÒÇÁÆ®¿þ¾î¸¦ È°¿ëÇÏ¿© ´Ù¾çÇÑ Chromatography columnsÀÇ »ç¾çÀ» Á¶ÇÕÇÏ¿©, ¿¬±¸½Ç¿¡¼­ ´Ù¾çÇÑ »ý¹° ºÐÀÚ Á¤Á¦ ¿ä±¸¸¦ ÃæÁ·½Ãų ¼ö ÀÖ½À´Ï´Ù.

Ư¡

  • °í¼º´É ½Ã½ºÅÛ ÆßÇÁ, °ËÃâ±â, ¹Í¼­ µî ´Ù¾çÇÑ Á¦¾î ¹ëºê´Â ¶Ù¾î³­ Á¤È®µµ¿Í ¹Ýº¹¼ºÀ» Á¦°øÇÏ¿© ±â´ëÇÏ´Â °á°ú¸¦ ½Å¼ÓÇÏ°Ô ¾òÀ» ¼ö ÀÖµµ·Ï º¸ÀåÇÕ´Ï´Ù.
  • ¸ðµâÇü ¼³°è´Â ½Ã½ºÅÛ À¯Áöº¸¼ö¸¦ ¿ëÀÌÇÏ°Ô Çϸç, °­·ÂÇÑ ½Ã½ºÅÛ ¼ÒÇÁÆ®¿þ¾î¿Í °áÇÕÇÏ¿© ´ÙÁß »ç¿ëÀÚ ·Î±×ÀÎ ¸ðµå¸¦ ÃæÁ·½ÃÅ°±â À§ÇÑ ¾÷±×·¹À̵带 ½ÇÇöÇÒ ¼ö ÀÖ½À´Ï´Ù.
  • »ùÇðú Á¢ÃËÇÏ´Â ¸ðµç ÆÄÀÌÇÁ¶óÀÎ ¹× ±¸¼º ¿ä¼ÒÀÇ ¿ì¼öÇÑ »ý¹°ÇÐÀû ÀûÇÕ¼º, ±×¸®°í protein activityÀÇ ¿ÏÀüÇÑ º¸È£¸¦ Á¦°øÇÕ´Ï´Ù.
  • ÇØ´ç ¼ÒÇÁÆ®¿þ¾î´Â GLP/GMP ±ÔÁ¤ ¹× FDA 21 CFR Part 11 ¿ä±¸»çÇ×À» ÁؼöÇÕ´Ï´Ù.
  • ÇØ´ç ¼ÒÇÁÆ®¿þ¾î´Â ¿ÏÀüÇÑ ±â´É, ¿ì¼öÇÑ »ç¿ëÀÚ °æÇèÀ» Ư¡À¸·Î ÇÏ¿©, ´ÙÁß ·¹º§ »ç¿ëÀÚ ±ÇÇÑ°ú ¿ÏÀüÇÑ °¨»ç ÃßÀû ¿ä±¸ »çÇ×À» ÃæÁ·½Ãų ¼ö ÀÖ½À´Ï´Ù.
Model No. Bio-Lab 30 Bio-Lab 100 Bio-Lab 300
System Pump Binary piston pump, PEEK, titanium alloy or 316 L stainless steel, good biological compatibility; pump head self-washing functionprevents pollution and salting out, and electronic pressure fluctuation compensation measures provide excellent gradient accuracy and repeatability for lab chromatography system to ensure the reproducibility.
Flow Rate Range(ml/min) 0~30 0~100 0~300
Pump-max pressure(MPa) ¡Â30 ¡Â20 ¡Â15
System-max pressure 1.3Mpa£¨Customized 0-8Mpa£©
Flow Rate Accuracy ¡¾1.0%
Gradient Model Linear, isocratic, and stepwise elution gradients which modify the gradient ratio online
UV Detector Two channel UV detector, deuterium lamp (standard), tungsten lamp (optional)
Wavelength Range(nm) 190-400
Absorbance Range(Au) -5~5
Wavelength Accuracy ¡¾1nm
Conductivity Detection Range 1~999 mS/cm£¬error of ¡¾3%
pH Detection Range 0~14£¬error of ¡¾0.05pH£¬ 0.01pH Resolution
Valve Standard: 2-channel inlet valve*2; Column position valve; Injection valve; 2-channel collection valve
Sensor Air sensor and Pressure transmitter
Mixer(ml) 0.6¡¢2¡¢5¡¢10
Software Workstation Bio-lab¢çChromatographic work station
Power(kw) 1 1 1
Dimensions£¨cm£© 450*585*604 450*585*604 620*550*675
Joint specification 1/16",1/8" 1/16",1/8" 1/8",1/4",3/16"
Detector  
UV Detector Ecom four-channel detector£¬200-800nm
Differential Refractive Detector RI-501¡¢RI-502¡¢RI-504

Sample Pump  
Flow Rate Range(mL/min) High accuracy piston pump
0-30/0-100/0-300

Sensor  
Air sensor Optional dual branch Air sensor

Pressure Sensor Optional post-column Pressure Sensor

Valve  
Inlet Valve 4- channel inlet valve or 8- channel is optional

Multifunctional Column 4-channel column position valve or 6-channel or

Position Valve 8-channel is optional

Outlet Valve 4- channel outlet valve or 8- channel is optional